MS1-16ZSW0-A020 Snap Action Switch SPDT #250 Terminals

Series:MS10 series

Description:

Type:MS1-16ZSW0-A020
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Throw (SPDT)
Terminal form:#250 Quick-connect Terminal
Mounting:via side mounting holes
Protection:IP40

Contact Now

  • Applications
  • Technical parameters
  • Remarks

Widely used in home appliance, electronic equipment, automatic machine,
communication equipment, car electron, apparatus and instrument, electric motion tool etc.

Rice cooker
Slow cooker
Electric Heating Faucet
Shredder

Baby chair
CNC machine tools
Power generator
Test equipment

Air conditioner
Water heater control panel
Bathroom products
Vacuum cleaner


3.DETAIL SPECIFICATIONS
Type:MS1-16ZSW0-A020
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Throw (SPDT)
Terminal form:#250 Quick-connect Terminal
Mounting:via side mounting holes
Protection:IP40
3.1OPERATING CHARACTERISTICS

Characteristics

Units

Standards

Note

Actuating Force

N

0.15 Max

Original 0.15 Max

Release Force

mm

0.05  Min

Original 0.05 Min

Operating Position

mm

14.7 ± 0.5

Original 14.7 ± 0.5

Note:
Actuating Force:
The force required to move the actuator from the free to the operation position
Release Force
The force allowed the mechanism to reset actuator after operation
Free Position
The position of the actuator when no external force is applied
Operating Position
The position of the actuator when contact change-over take place
Movement Differential
The distance between operation and release position           

3.2 General
3.2.1 Application This specification is applied to MS10 Micro Switch used for electronic equipment.
3.2.2 Operating Temperature range -25℃ ~ +105℃
3.2.3 Test condition Unless otherwise specified. The atmospheric conditions for making measurements                

And tests are as follows:
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. It shall be conducted at the following conditions.
Ambient Temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
3.3 Appearance Construction and Dimension
3.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.3.2construction and dimensions Refer to individual product drawing.
3.4. Electrical Specifications

NO.

Item

Test Condition

Criteria

3.4.1

Contact Resistance

Shall be measured at 1A,5V DC by voltage

 drop method after some operations 

without load.

Applied position: Between terminal “C” and terminal “NO”.

50mΩ MAX

3.4.2

Insulation Resistance

Test voltage:500VDC, measured after 1 min ±5s

Applied Position: applied position: 
1)Between terminal “C” and terminal “NO”

2)Between terminal and ground

100MΩ MIN

3.4.3

Voltage proof

Following test voltages shall be applied for 1 min.

1)Between terminal “C” and terminal

 “NO”:1000VAC (50~60Hz)

2)Between terminal and ground: 1500V AC(50~60Hz)

No dielectric 

breakdown 

shall occur

3.5. Durability

NO.

Item

Test Condition

Criteria

3.5.1

Cold

After testing at -25±2℃ for 96 h,

 the switch shall be allowed to stand 

under normal room temperature 

and humidity condition for 1h, and 

then measurement shall be made 

within 1 h. water drops shall be 

removed.

Contact 

resistance

(item 4.1): 

100mΩ MAX

Insulation 

resistance 

(item 4.2):

50MΩ MIN

Voltage 

proof: 

(item 4.3)

No dielectric 

breakdown 

shall occur.

Within 10%

of specified
value .

No 

abnormalities 

shall be 

recognized 

in appearance 

and construction

 

3.5.2

Dry heat

After testing at 105±2℃ for 96 h,

 the switch shall be allowed to stand 

under normal room temperature 

and humidity condition for 1h, and 

then measurement shall be made 

within 1 h.

3.5.3

Damp Heat

After testing at 40±2℃ and 

90-95%RH for 96 h, the switch shall be 

allowed to stand under normal 

room temperature and humidity 

condition for 1h, and then 

measurement shall be made within 1 h. 

water drops shall be removed.

3.5.4

Change of Temperature

After 5 cycles of following conditions 

the switch shall be allowed to 

stand under normal room 

temperature and humidity condition for 

1h, and then measurement 

shall be made within 1 h. water drops 

shall be removed.

3.6 Durability

NO.

Item

Test Condition

Criteria

 

3.6.1

 

Endurance

(According to

 UL61058)

 

1/4hp 125VAC

Switch shall be operated according to following 

sequence

(Test1~Test2)

 

Voltage

Current

Power

 Factor

Operation

 Rate

Operation

 Cycles

Test 1

125V

34.8 A

0.4-0.45

6-10

Cycles/min

50cycles

Test2

125V

5.8 A

0.75-0.8

6-10

Cycles/min

50000

cycles

Voltage proof:Test voltage shall be applied for 

1 min(50~60Hz, Cut-off current:0.5mA)

 

6GPA 125/250VAC; 6A 30VDC

Operation Cycles:50,000 次 ;

Operation Frequency:15~20 /min

Voltage proof:Test voltage shall be applied for 

1 min(50~60Hz, Cut-off current:0.5mA)

 

Insulation 

resistance

(item 4.2):

50MΩ MIN

Voltage 

proof:

Terminal and 

terminal:

1000VAC

No dielectric 

breakdown

 shall 

occur.

 

Operating 

characteristic

(item 5.1):

Within 20% 

of specified
value .

 

6000 cycles

temperature 

rise: 30℃ 

MAX

10000cycles 

temperature 

rise: 55℃ 

MAX

No 

abnormalities 

shall be 

recognized in 

appearance 

and 

construction.

 

3.6.2

 

Endurance

(According to

 EN61058-1

/IEC61058-1)

 

6GPA 125/250VAC

6A 30VDC

Operating Cycles:50,000 cycles 

Operation Frequency:15~20 cycles/m 3(0.5)A 250VAC 

Voltage proof:Test voltage shall be applied for 

1 min(50~60Hz, Cut-off current:0.5mA)

 

 

Insulation 

resistance

(item 4.2): 

50MΩ MIN

Voltage 

proof:

Terminal 

and terminal:

750VAC

Terminal and 

ground:

1500VAC

No dielectric 

breakdown 

shall occur.

Operating 

characteristic 

(item 5.1):

Within ±20%

 of specified
value .

Temperature 

rise:55℃ MAX

No 

abnormalities 

shall be 

recognized 

in appearance 

and construction

 

 

 

4. DRAWING & DIMENSION

 


 


 

5. CIRCUIT DIAGRAM

 

 

 

6.  PACKING:

6.1

 Packing material:

Plastic box / 
Double-layers paper carton

6.2

 Packing number:

100 pieces per box 
4 inner cartons per shipping carton
Each shipping carton 10000 pieces

6.3

Weight:

Gross Weight:  8.5kg

 Net Weight:  7.0kg

6.4

 Size:

31.0 x 25.0 x 34.5 CM / 0.045CBM

SAFETY APPROVAL & RATING:

Approved Rating

Mark

Reference No.

16A 125V AC


UL&CUL

E176213

 

VDE

 

16(4)A 250V AC μ10T125 5E4

CQC

CQC05002012548

 

NEMKO

 

16(4)A 250V AC μ10T125 5E4

SEMKO

1018901

 

FIMKO

 

 

DEMKO

 

16(4)A 250V AC μ10T125 5E4

CE

SH10030591-V1

 

TUV

 

16(4)A 250V AC μ10T125 1E4

ENEC

SE/0488-03

ENEC-00376-A2-M1

 

EK

 

 

CB

 

 PARTS LIST

NO.

QUANTITY

Item

Material

1

1

plunger

Engineering plastic PBT WHITE

2

1

Lever

Stainless steel SUS304
3 1 case Engineering plastic PBT WHITE

4

1

Moving piece

Beryllium alloy QBe2

5 1 Spring Stainless steel SUS304

6

1

support

The brass strip H62 Plate with silver

7

1

contact

AgNi10/Cu

8 1 contact AgNi10/Cu

9

1

NO terminal

The brass strip H65 Plate with silver

10

1

NC terminal

The brass strip H65 Plate with silver

11

1

Cover

Engineering plastic PBT WHITE

Note: Returned plastic should not exceed 20%.

return