NE8013-TNCQ-H-SW3P 2Ways 3 Pins Metal ON-ON Rocker Arms Toggle Switch
Series:NE8013-TNCQ-H-SW3P
DETAIL SPECIFICATIONS:
Type: NE8013-TNCQ-H-SW3P
Rating: 5A@125 VAC or28VDC (Q contact)
Function: DPST
Terminal form: Solder Terminal
Mounting: Whole embedding
Protection: Comply with IP40
- Applications
- Technical parameters
- Remarks
-
1.Digital Products: digital camera, digital video and so on;
2.Remote Control: the remote control of automobile domestic security products;
3.Communication Products: mobile phone, vehicle-mounted phone, telephone set, building equipment, PDA and so on;
4.Homehole appliances: TV set, microwave oven, electric rice cooker, electric fans ,refrigerator,washer;air-conditioning and so on;
5.Security Products: visual interphone, monitor and so on;
6.Toys: electric toys and so on;
7.Computer Products: PC camera and so on;
8.Exercises Machines: treadmills, massage armchair and so on;
9.Medical Device: sphygmomanometer, thermometer, hospital call system and so on;
10.Others: laser pen ,Pointer,Wireless mouse remote control pen,Laser projection pen,page turner,electronic pen;MousePen;overhead projector and so on;
11.Operating switches in all types of electronic equipment such as audio devices, office devices, communication devices, measuring instruments, TVs, video recorders,automotive sets, etc.
12.Household appliances, electric force, telecommunications, machine tool, vessel, textile, printing, Mining machine, Music Instrument, etc.
1. DETAIL SPECIFICATIONS:
Type: NE8013-TNCQ-H-SW3P
Rating: 5A@125 VAC or28VDC (Q contact)
Function: SPDT
1.1 OPERATING CHARACTERISTICS
NO.
ITEM
TEST CONDITIONS
PERFORMANCE
1.1.1
Operating Force
The test point is 3mm away from the rubber handle. After three times, the test is carried out.
10N max
1.1.2
Terminal Strength
In the front row of feet, any square type plus (500gf) strength test will take 15 seconds.
There are no cracks, loosening and other abnormalities in the terminals to meet the mechanical and electrical properties.
1.1.3
Shank strength
The force of 1Kgf is applied at the front of the handle, and the displacement should be fixed along the direction of the mark.
There is no serious deformation of the handle, and it can work normally.
Actuating Force:
The force required to move the actuator from the free to the operation position
1.2 GENERAL CHARACTERISTICS
1.2.1 Application: This specification is applied to NE8013 Toggle Switch used for electronic equipment.
1.2.2 Operating temperature range:-30℃~+85℃
1.2.3 Test conditions : Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
1.3 APPEARANCE, STRUCTURE AND DIMENSION
1.3.1 Appearance :Switch shall have good finishing, and no rust crack or plating failures.
1.3.2 Construction and dimensions: Refer to individual product drawing.
1.4. Electrical specifications
NO.
ITEM
TEST CONDITIONS
PERFORMANCE
1.4.1
Contact
resistanceThe 2-4VDC is tested under tiny current (below 100mA), silver plated or gold plated.
10mΩ MAX
1.4.2
Insulation
resistanceInput 500V DC voltage for 1 minutes, test according to the following contact mode:
(1)Between the terminal.
(2)Between the terminal and the outer shell.
1000MΩ MIN
1.4.3
Pressure resistance
Measurement of AC 1500V (50-60 Hz) between open contacts and poles
Measurement of AC 3000V (50~60Hz) between terminal and grounding
Fixed time: 1 minute eachNo abnormality, such as insulation damage
1.5 Endurance
NO.
ITEM
TEST CONDITIONS
PERFORMANCE
1.5.1
Operation Life
Measurements shall be made following the test set forth below:
3A,250VAC resistive load
Rate of Operation:6~8cycles/minute
Cycle of Operation:6000cyclesAs show in item 3.4
1.6 ENVIRONMENT RESISTANCE
NO.
ITEM
TEST CONDITIONS
PERFORMANCE
1.6.1
Resistance Low Temperature
Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before measurements are made
Time:48 hours
Temperature:-30±3°CAs show in item 2~6
1.6.2
Resistance high Temperature
Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before measurements are made
Time:48 hours
Temperature:85±3°C1.6.3
Resistance Humidity
Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before measurements are made
Temperature:40±2°CRelative Humidity:90-95%
Time:48 hours1.7 SAFEKEEPING METHOD:
(1)If the product is not used immediately, it should be kept at normal temperature without direct sunlight and corrosive gases.
In the environment. But we recommend that we use it as soon as 6 months.
(2)Put the finished products in plastic bags and seal them in the same environment as soon as possible, and use them as soon as possible. Do not overlay excess when saved in order to prevent the pressure from breaking.
(3)Do not overlay excess when saved in order to prevent the pressure from breaking.
2. DRAWING & DIMENSION:
3.CIRCUIT DIAGRAM:
PART LIST:
No.
Name
Material
1
Plastic Base
nylon
2
ACTUATOR
nylon Copper alloy,chrome plated with internal O-ring standard;nylon
3
Plastic Enclosure
nylon
4
END CONTACTS
Copper alloy, silver plated (Q contact material )
5
CENTER CONTACTS & ALL TERMINALS
Copper alloy, silver plated (Q contact material)
6
TERMINAL SEAL
Epoxy
7
Nut & Locking Ring
Brass,nickel plated
8
Lock washer
Steel
PACKING:
1
Packing material:
Plastic bag
Double-layers paper carton
2
Packing number:
X pieces per box X inner cartons per shipping carton Each shipping carton X pieces
3
Weight:
Gross Weight : xx kg
Net Weight : xx kg
4
Size:
X x Xx X CM